070015E0 pages
700-15
Issue 02-13*
THROTTLE CHECK VALVES
single valve with threaded pipe connection, pmax. 500 bar
G1/4
A/F 24
23,5
32
Webcode: 070015
G
G1/4
F
Other designs
are available
on request
52
Technical data:
Description:
Type
Variation
Adjustability
Max. operating pressure (pmax.)
Max. volume flow(1) (Qmax.)
[bar]
[l/min]
Weight approx.
Order no.
[kg]
The throttle check valve belongs to the flow
control valves. The throttle check valve is used
with single- and double-acting consumers.
Herewith, it affects the volume flow.
Throttle check valve
Single valve for pipeline connection
Can be adjusted manually
500
15
- Throttled flow from GF
- Free flow from Flow FG
0,18
DRV-500-5-001
Advantages:
(1)
Value applies to a fully opened valve and a resistance to flow of approx. 50 bar
in throttled direction.
Easy adjustable by hand throttle
Easy installation by
threaded connections
Installation without additional
fastening materials possible
p-Q nominal lines (guide values) for kinematic oil viscosity during the
-6
measurements 36 x 10 m²/s., throttle fully opened;
Flow GF
Flow FG
35
3,5
3,0
Pressure drop p (bar)
30
Pressure drop p (bar)
Suitable for single-acting and
double-acting consumers
25
20
15
10
5
0
0
5
10
Volume flow Q (l/min)
15
20
2,5
2,0
1,5
1,0
0,5
0
0
5
10
15
20
Volume flow Q (l/min)
HYDROKOMP
®
Hydraulische Komponenten GmbH
Siemensstraße 16, 35325 Mücke (Germany)
Phone: +49 6401 225999-0
Fax:
+49 6401 225999-50
E-mail: info@hydrokomp.de
Internet: www.hydrokomp.de
700-15 / 02-13 *Subject to change without notice, compare issue no. at www.hydrokomp.de
1
"