HPQ280673 Series Element Upgrade Datasheet0 pages
Performance
Temperature:
Buna (Standard): -45oF ~ 225oF, -43oC ~ 107oC
EPR (optional): -65oF ~ 300oF, -53oC ~ 148oC
Viton (optional): -20oF ~ 250oF, -29oC ~ 121oC
Element Burst: 150 DP psi, 10 DP bar
Media Efficiency: b25[c] > 1000 (25 micron absolute)
High Performance Coalesce Element
Upgrade for Facet CR-22 Cellulose
Media Coalesce Element.
HPQ280673
Hy-Pro Glass Media Coalesce
Element Upgrade
Coalesce Element Upgrade
Fluid Compatibility (No Media Breakdown)
Compatible with synthetic and Petroleum based
turbine oils, #2 Diesel, Heavy Diesel, and Specified
Bio-Diesel fuels.
Hy-Pro glass coalesce elements are impervious to
media breakdown from long term exposure to water or
oil with high concentrations of dissolved, emulsified and
free water.
Antiquated coalesce elements that utilize treated
cellulose media are susceptible to a loss of water from
oil separation efficiency and media migration (mush).
Media breakdown can occur when treated cellulose is
exposed to high concentrations of water or from long
term exposure to water in oil.
Interchange (See Interchange Guide for
Elements not Listed)
Facet Hy-Pro
CR-22 HPQ280673
Media
G8 Glass media pleat pack is impervious to media
degradation from high concentrations of water in oil,
extended fiber contact with water (saturation) or
submersion in straight water on the bottom of the
coalesce vessel.
Water Removal (High Efficiency)
The glass media coalesce utilizes smaller fiber size
allowing a higher volume of fibers in the media yielding
more fiber surface area for water droplet collection and
coalescence. The coalesce element causes collects
the small emulsified water droplets on the glass fibers
where they coalesce together to form larger,
suspended water droplets. The higher specific gravity
of the water causes the larger suspended water droplets
to fall to the bottom of the coalesce vessel forming
a clear separation between water and the oil floating on
top of the water where the water can be removed.
Tested to ISO Quality Standards
ISO 2941 Collapse and burst resistance
ISO 2942 Fabrication and Integrity test
ISO 2943 Material compatibility with fluids
ISO 3724 Flow fatigue characteristics
ISO 3968 Pressure drop vs. flow rate
ISO 16889 Multi-pass performance testing
www.hyprofiltration.com
Ph 317.849.3535 HY-PRO FILTRATION