HPQ290960S Filter Elements0 pages
Performance
Temperature: -20oF ~ 250oF, -29oC ~ 121oC
Standard Element Collapse: DP 5000 psi, DP 340 bar
Materials: 304, 304L, 316 or 316L Stainless Steel
Fluid Compatibility: De-Ionized Water
High Performance Filter Elements for
Combustion Turbine Air Intake Misting
(fogger) Systems for Cooling Intake Air.
HPQ290960S Series
Hy-Pro Filter Element Upgrades for Pall
HC2116EN* Series Elements.
HPQ290960S Element
Application Info
Combustion turbines (ie GE Frame 7) are equipped
with misting / fogging water spray systems for cooling
of intake air. High pressure in-line filters are used to
protect injector spray nozzles from pump seal debris,
pump abrasive wear debris and contaminated water
supply. CT air intake misting systems are typically
found on turbines installed in hot temperature climates.
Fluid Compatibility
Stainless steel components and pleated mesh are
utilized to ensure compatibility in De-Ionized water.
Tested to ISO Quality Standards
ISO 2941 Collapse and burst resistance
ISO 2942 Fabrication and Integrity test
ISO 2943 Material compatibility with fluids
ISO 3724 Flow fatigue characteristics
ISO 3968 Pressure drop vs. flow rate
ISO 16889 Multi-pass performance testing
Interchange
Pall Hy-Pro
HC2116ENMYR74 HPQ290960S-40W
www.hyprofiltration.com
Ph 317.849.3535 HY-PRO FILTRATION
CT Air Intake Mister System
CT Air Intake