ACS 30ER-Series0 pages
ACS30ER_Datasheet table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:11.00pt "Arial", sans-serif; } .font3 { font:13.00pt "Arial", sans-serif; } .font4 { font:17.00pt "Arial", sans-serif; } .font5 { font:8.00pt "Georgia", serif; } .font6 { font:7.00pt "Tahoma", sans-serif; } Phone: +49 7231 58905-0 www.huhn-rohrbacher.de Fax: +49 723158905-11 info@huhn-rohrbacher.de AC/DC - Converter 19"-Eurostandard Օ EMI Compliant Design 3 U/4 HP/160 mm Օ Wide Range Input 92 ... 264 Vac Single Output 30 Watt Technical Specification ACS 30ER-Series Input Input range Hold-Up Time @ Vin = Vmmm, Ltnom Efficiency Input Protection Vin: 92 ... 264 Vac/47 ... 63 HZ; Vonom = 115 / 230 Vac 10 ms (Vin = 115 Vac); 60 msec (Vin = 230 Vac) at full load 70 % ... 80%, device dependant varistor and non-resettable fuse 1AT/250V Output Ouput Voltages Vo see table at the end of the document Adjustment range of Vo Yes, +/-5 % Vonom (nominal voltage) Output Currents Io see table at the end of the document Ripple + Spikes, Measurement Bandwidth 20Mhz 50 mV +1.5 % Vonom Short Circuit Protection Yes, electronic current limiting Overvoltage Protection optional Line Regulation (Vՙ ... Vinmax) < 0.2 % Vonom; Io = constant Load Regulation (10% ... 90%) > 0.2 % Vonom; Vin = constant Temperature Coefficient < 0.02% Vo / K Settling Time (10...100 % Ut); di / dt = 1A / usec < Imsec Under- / Overshoot for Pulsed Load < 6 % Vonom Page 1/3
"