DCS 240 RDPF-Series0 pages
ACD50ER_Datasheet table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:11.00pt "Arial", sans-serif; } .font3 { font:12.00pt "Arial", sans-serif; } .font4 { font:17.00pt "Arial", sans-serif; } DC/DC-Converter 19"-Eurostandard Soft Switching EMI Compliant Design 3 U / 14 HP / 220 mm Wide Range Input 16 ... 40 Vdc Single Output 240 Watt Hot Plug In, Redundant n+1 Current Share Bus Safety Approvals Technical Specification DCS 240 RDPF-Seru Input Input range Vm: 16 ... 40 Vdc Efficiency > 80%, typically Input Protection Transient Suppressor and internal fuse, slow blow 1AT/250 V Output Ouput Voltages Vo see table at the end of the document Adjustment range of Vo -8...+ 17% Vo Output Currents Io see table at the end of the document Ripple + Spikes, Measurement Bandwidth 20Mhz 50 mV Short Circuit Protection Yes; by internal current limiting Overvoltage Protection Yes, adjustable Power-Good Yes, floating relay contacts Line Regulation (Vinmin ... Vinmax) < 0.2% Vonom; Io = constant Load Regulation (10% ... 90%) < 1.5% Vonom; Vin = constant Temperature Coefficient < 0.02% Vo / K Settling Time (10...100% U); di / dt = 1A / usec < 1msec Under- / Overshoot for Pulsed Load < 5% Vonom, typcally 3% Redundancdiode Yes, embedded Operation in parallel up to 3 converter; Power division by current share bus Page 1/3
"