H501-5110 pages
Submersible drainage pumps
jacket cooled
for clear water and drainage water.
H 501 - H 511
Application
HOMA H 501 – H 508 are wear resistant submersible drainage pumps for
pumping clear water or drainage water
with abrasive sand or mud additives.
They are used to pump surface water
from sumps, subways and building
sites, for supply of industrial water,
applications on board ships etc. The
water jacket cooled motor with the top
discharge protects the motor against
overheating even during sip operation.
DIN EN 12050-2: Conformity and
design approved and controlled by LGA,
certificate No. 0220119.
Installation: Transportable or permanent. Models with float switch control
for automatic pump operation, depending on liquid level in the sump.
Pumped liquid: Clear water or
drainage water with abrasive (e.g. sand)
solids. Max. liquid temperature: 35°C,
short term up to 60°C.
Operation: Intermittent.
Design
Fully submersible, compact integrated
motor-pump unit consisting of:
Pump: Single stage centrifugal
pump with vertical discharge.
Impeller: Open multi-channel impeller, spherical clearance 10 mm.
Motor: Fully submersible, pressure
tight electric motor, oil-filled. Insulation class F. Motor protection IP 68.
Cable connection chamber totally isolated from motor housing. All 1 phase
models with thermal sensors embedded in motor winding.
Cablel:
Model W: H07RN-F3G1
Model D: H07RN-F4G1
Model H508W: H07RN-F4G1
Model H508WA: H07RN-F5G1
Model H511: H07RN-F4G1,5
Shaft/Bearing: Large diameter
stainless steel rotor shaft, pre-lubricated
bearings.
Seals: Combination of mechanical
seals with lip seal.
Performances
18
H (m)
16
14
12
10
8
6
1
4
3
2
4
2
0
H 502, H 506
0
1
0
H 511
4
2
8
3
4
5
6
7
8
9 10 11 ( l / s )
Q
12 16 20 24 28 32 36 (m 3/h)
Technical Data
Curve
No.
Pump type
Motor
input
P1 (kW)
Motor
output
P2 (kW)
H
H
H
H
H
H
H
H
H
H
1,2
1,2
1,0
1,5
1,5
1,5
2,0
2,0
3,0
3,0
0,8
0,8
0,8
1,1
1,1
0,9
1,3
1,1
1,9
1,9
501
502
502
505
506
506
508
508
511
511
W(A)
W(A)
D(A)
W(A)
W(A)
D(A)
W(A)
D(A)
W(A)
D(A)
Speed: 2900 rpm
Model W: 230V/1Ph
Model D: 400V/3Ph
Materials
Motor housing
Impeller
Pump housing,
Suction cover
H501-H508
H511
Mechanical seal
steel
Seal kit
Stainless steel
Stainless steel
Stainless steel, rubberized
Aluminium / Rubber
Carbon graphite/Chrome
NBR
Equipment supplied
Models H 502, H 506, H 508 and H 511
with STORZ-fixed coupling (size C).
Model W (230-240V/1Ph):
H 501-H 508 with 10 m of cable, H 511
with 20 m of cable. Models H 501 and
H 505 supplied with cable and plug.
Models H 502 and H 506 supplied with
Capacitor*
(µF)
30
40
Nominal
current
(A)
Discharge
6,0
6,0
2,2
6,9
6,9
2,7
10,0
3,5
13,5
4,8
BSP
BSP
BSP
BSP
BSP
BSP
BSP
BSP
BSP
BSP
11/2“
11/2“
11/2“
11/2“
11/2“
11/2“
2“ F
2“ F
2“ F
2“ F
Weight
(kg)
F
F
F
F
F
F
9
9
9
11
11
11
18
18
25
25
Model A: With automatic level control
HOMA-Nivomatik
* Capacitor: For the operation it is necessary to install a capacitor in the control box.
control box W01 fitted with overload
protection, on-off-switch. Model H 508
and H 511 with control box W19 fitted
with overload protection, on-off-switch
and capacitor.
Model D (400-415V/3Ph): Supplied
with control box D32 fitted with overload
protection, control of direction of rotation, on-off-switch, 10 m of cable (H 502,
H 506 and H 508) or 20 m of cable
(H 511) and phase inverter.
Model A: With additional automatic
level control float switch. Models H502
WA and H506 WA with control box
WA/01 and manual-auto-switch. Model
H508 WA with control box WA/19, manual-auto-switch and overload protection.
Model H511 with control box WA/19,
manual-off-switch and overload protection. Model DA with