ISE30 pages
P0756-P0822-E.qxd
08.8.27 6:36 PM
Page 763
LCD Readout Digital Pressure Switch
Series ZSE3 (For Vacuum) / ISE3 (For Positive Pressure)
For General Pneumatics
Easy pressure setting with the digital
display
Can be integrated with a vacuum unit,
Series ZX
ZSE
ISE
ZSP
PS
ISA
PSE
IS
ISG
ZSM
Built-in failure prediction output function
When system performance declines due to filter
element clogging, worn vacuum pads, piping leakage,
etc., the switch can detect and indicate an oncoming
problem before failure occurs.
Two independent outputs
Allows the calibration of two different setpoints e.g.
change of vacuum pad size requiring different setpoints,
two different supply pressures requiring different
pressure confirmation points.
Calibration data
The calibration data is stored in an EEPROM. The
EEPROM is rated to keep its memory for 100,000 hours
(approx. 11 years) without having power supplied.
Suction filter comes as standard
Self-diagnostic function
Excessive current
Excessive pressure
Data error
LCD:
Error display
SMC
kPa
Indication lights:
LED (Red)
RESET SET
763
"