SNP-X12 Series0 pages
General Purpose t
Rated 120W
SNP-X12 Series
ITE & Medical Safety
Features:
●t
Meet Energy Star Version 2.0
●t
With built-in active PFC
●t
Only 1.36 inch height
●t
5.8 Watt per cubic inch
●t
With ITE & Medical safety
●t
Efficiency between 85% to 90%
●t
Operation from -20oC to 70oC by convection
General Specifications:
Input voltage ......................................... 90 VAC to 264 VAC
Input frequency ............................................. 47 Hz to 63 Hz
Inrush current ................................. less than 30A at 115VAC
t
less than 60A at 230VAC
t
cold start, 25oC
Efficiency ............................................................ 87% typical
Hold up time ..................................................... 20mS typical
t
at rated load and 115VAC
Average efficiency ............t> 87% at 25%, 50%, 75%, 100%
t
of rated load and 115VAC/230VAC input
No-load input power ..................................................t< 0.5W
Energy saving .........................................t energy star Ver. 2.0
Over load protection ........................................tauto recovery
Mechanical Specifications:
Short circuit protection.....................................tauto recovery
Over voltage protection ............................................tlatch off
Max. capacitive load ................................................ 30000uF
Remote Sense ............. compensates for 0.5V load drop min.
Operating temperature (open frame type) .......... -20oC to 70oC
t
derating: 2.5% / oC > 40oC
Cooling .................................... free air convection for 120W
t
with 18CFM forced air flow for 130W
Storage temperature ...................................... -20oC to +85oC
EMI ................................................. EN55022 "B", FCC "B"
Harmonics ........................................................ EN61000-3-2
EMS ......................................... EN61000-4-2,-3,-4,-5,-6,-11
Safety ................................................... UL60950-1 : (cULus)
t
EN 60950-1 : 2006 +A11 (TUV)
t
ANSI/AAMI ES60601-1 : 2005 (cULus)
t
EN 60601-1 : 2006 (TUV)
SNP-X127
TO CHASSIS GROUNDING
o4.0 TYP. MOUNTING HOLES
x4
127.0
Notes:
TB1
L
N
64.8
1
TRANSFORMER
5.0
5.0
34.6 Max.
115.6
TO CHASSIS GROUNDING
76.2
1.t
t
2.t
t
t
3.t
t
t
t
4.t
t
t
t
Dimensions shown in mm as left.
Tolerance: +/-0.4mm.
Size:
76.2 X 127 X 33.5 (mm)
3" X 5" X 1.319"
Packing:
Net weight: 290 g approx. / unit
Gross weight: 13.0 kg approx. / carton, 36 units / carton
Carton size (mm): 339 (L) x 339 (W) x 327 (H)
Connectors:
AC input : Molex 5277-02A or equivalent
DC output : Molex 5273 or equivalent
Remote Sense : Molex 5045-02A or equivalent
2.4 Max.
-Steven-
JUL. 2013
** This data sheet is only for models selection. For business, engineering specification by model must be used.
4-1
"