SLSP Brochure0 pages
SLSP Standard Series-order codes
Connector
0 F
SUPPORT Location flats
JxK j
Capacity | Order | A | B | C | D | E | F | G | H | / | J | K | L | T | Weight(kg) |
6.5t | SLSP6500S000XX | 10.0 | 22.5 | 80 | 25.0 | 19.0 | 42.0 | 5.0 | 22.0 | 36.0 | 33 | 34 | 142.5 | 1" x 8 tpi UNC | 0.9 |
12t | SLSP012TS000XX | 15.0 | 31.5 | 115 | 35.0 | 25.0 | 52.0 | 8.5 | 32.0 | 51.0 | 41 | 42 | 191.5 | 1-3/8" x 6 tpi UNC | 1.8 |
25t | SLSP025TS000XX | 20.0 | 46.0 | 165 | 50.8 | 42.0 | 63.0 | 11.0 | 46.0 | 73.0 | 54 | 55 | 266.0 | 2" x 4.5 tpi UNC | 4.5 |
55t | SLSP055TS000XX | 25.0 | 63.0 | 235 | 70.0 | 62.0 | 88.0 | 15.0 | 65.0 | 105.0 | 74 | 75 | 358.0 | 2-3/4" x 4 tpi UNC | 12.1 |
Typical Specifications*
Signal Output at Capacity.....................1.3 ~ 1.5 mV/V
Linearity Error.......................................< 0.500% FSO
Non-Repeatability.................................< 0.050% FSO
Combined Error....................................< 1.000% FSO
Hysteresis............................................< 0.100% FSO
Creep/(30 mins.)..................................< 0.100% FSO
Zero Balance........................................< 1 % Capacity
Temperature Effect on Span(/10C)........< 0.030% FSO
Temperature Effect on Zero(/10C).........< 0.070% FSO
Operating Temperature Range..............-20 ~ 60 C
Storage Temperature Range.................-50 ~ 85 C
Service Load...........................100% Capacity
Safe Load...............................150% Capacity
Safe Side Load.......................100% Capacity
Ultimate Load..........................300% Capacity
Input Resistance.....................800Q ± 50Q
Output Resistance..................705Q ± 50
Insulation Resistance..............> 5000 MO (@50 VDC)
Excitation Voltage(Rec)...........5-20 VAC/DC
Excitation Voltage(Max.)..........25 VAC/DC
Cable (screw connector).........M12 male 4 pole
Material...................................17-4PH Stainless Steel
• * Specifications may vary depending upon installation and loading specifics.
• Construction is welded stainless steel 17-4PH, IP67, potted with DoubleSeal protection.
• The Standard Series SLSP fits a standard 2130 High Load shackle and can be purchased with optional
centering sleeve and anti-rotation cleat.
• The SLSP is fitted with an integral M12 4 pole male sensor connector and supplied with the mating
female connector. The mating connector accommodates PT cable packs diameter 4~8mm (not
supplied). The connector terminals are numbered and should be connected.
1- Excitation +ve, 2- Excitation -ve, 3- Signal -ve, 4-Signal +ve. For 6 wire cables connect the
appropriate Sense and Excitation wires to the same connector terminal.
The SLSP (Stainless Load Sensing Pin) is a practical measurement device and is rarely fitted to an installation
designed for precision weighing. Many of the variables eliminated from accurate weighing installations (side
loads, variable contact point, friction, bridging, twisting) cannot be eliminated from a SLSP installation and
consequently the performance becomes a compromise. Specifications quoted by PT are those typically
achieved under controlled conditions and do not necessarily represent installed conditions.
"