Manual Operation
• Pump comes standard with hand lever for precise pressure control, remote locations, or emergency back-up applications.
Technical Data: Liquid Side Specifications
• Service: Oil, Water or Water/Oil mixture and other fluids depending on material compatibility.
• Maximum Outlet Pressure: 31,900 psi (2,200 bar)
• Maximum Pressure Ratio: 1:213
• Volume Displacement Per Stroke: 0.035 in3 (.57 cm3)
• Inlet Connection: 3/8" FNPT
• Outlet Connection: Autoclave F250C-1/4" Female High Pressure
(Contact Autoclave Engineers for Additional Options)
Technical Data: Air Side Specifications
• Pump can be operated with air even with manual hand lever attached
• Air Drive Pressure Range: 15-150 psi (1-10 bar) *See note1
• Nominal air pressure required for 31,900 psi (2,200 bar)
output pressure is 148 psi (10 bar)
• Inlet Port: 1/4" FNPT
• Exhaust Port (muffler removed): 1/4" FNPT
• Air Consumption @ 90 psi: 20 SCFM
• Prelubricated at Factory
General Specifications
• Maximum Operating Temperature: 0-150º F (-18º to 65º C)
• Net Weight without Isolation Chamber: 9 lbs. (4.1 kg)
• Pressure Head: 316 Stainless Steel
• Plunger: 440 Stainless Steel
• Check Valve Glands: 15-5PH Stainless Steel
• Liquid Seal: See Ordering Guide for options
• Air Drive Seals: Buna N
Notes:
1. Maximum air drive pressure is limited by maximum output pressure.
2. Alternative materials for wetted parts and seals are available,
please contact Autoclave Engineers for additional information.