0729-1757-99 Instruction Manual0 pages
Page 1 of 4
Operating Manual
0729-1757-99
Single Axis
Programmable
Tilt Switch
1. PRODUCT DESCRIPTION
The single axis programmable tilt switch incorporates an electrolytic tilt sensor and micro-controller technology. One
of the special features is its ability to be field programmable by the user. It provides a wide-angle trip range and a
wide operating supply voltage range. There are 2 open collector outputs to indicate trip points. The unit will indicate
which direction the unit is tilted when the unit reaches the trip point. The center set point can be at any angle within
the specified range of the unit. The unit will retain the programmed trip points even when the power is removed. It
can be reprogrammed as often as necessary for multiple applications.
Open collector functionality: low/non-tripped, open/tripped. For opposite functionality (open/non-tripped, low tripped)
see the 0729-1758-99.
2. WIRING CONNECTIONS
The diagram shows the connections to power and output. Observe all voltage and current limits. Do not
exceed the open collector output current or the internal transistors can be damaged. The common (open
collector – green wire) is only used if a separate power supply is used for the loads. This common (open
collector – green wire) is internally connected the common (power supply – black wire).
Wire
Description
RED
BLK
GREEN
BLUE
GRAY
POWER
COMMON
OUTPUT
(LEFT)
OUTPUT
(RIGHT)
+4.5 to 28 VDC
×
Power/signal common
×
×
Power/signal common
×
×
Low /non-tripped 1
Open/tripped 1
200 mA (max)
Low/non-tripped 1
Open/tripped 1
200 mA (max)
NOTE 1: The outputs (left and right) are open collector.
The Fredericks Company l 2400 Philmont Ave ● HuntingdonValley, PA 19006-0067
Tel: 215.947.2500 l Fax: 215.947.7464 l Email: sales@frederickscom.com l www.frederickscom.com
0729-1757-99manual Revision: G