Patented Thin Film Glass Narrow Angle 0737-1203-990 pages
DATA SHEET
`
Operating Specifications
Description
The 0737-1203-99 “THIN FLIM” sensor is designed for
applications requiring highly repeatable mid-range angle
measurement and a linear output. Long-term stability over its
angle and temperature range is a distinctive characteristic of this
sensor. The 0737-1203-99 uses patented “Thin Film” technology
and construction to provide an accurate and robust angle sensor
at an attractive price with excellent sensor-to-sensor
repeatability and reliability. Unparalleled performance and
features compared to any other commercially available product.
Angle Range
Resolution
Null Repeat
15 arc min.
<0.05 arc sec.
< 0.5 arc-sec.
Applications Include
»
»
»
»
»
Geophysical and Structural Monitoring
Construction Laser Instruments and Transits
Solar Tracking and Satellite Positioning
Machine Tool / Platform Leveling
Medical Positioning and Monitoring
Patent: US 7,886,451
15’
Operating Range (max.)
Linear Range
± 8’
Null Voltage
≤0.030 Volts
Null Current(max.)
0.2 mA (continuous)
Null Impedance (nom)1
80KΩ (25°C)
(measured left to right electrode) see fig 2
Null Repeatability
< 0.5 arc seconds
Resolution
< 0.05 arc seconds
Symmetry (typ)
≤20%
-20 C to +100 C
Operating Temperature
-50 C to +125 C
Storage Temperature
Time Constant (1)2
< 500 msec
Materials
non-magnetic
Temperature Coefficient
0.05%/°C
at null when properly mounted
1
Impedance of the electrode may be changed to limit null
current.
2
Viscosity of the electrolyte may be modified to meet
individual requirements for time constant or vibration.
Physical Dimensions
Vial length
Vial Diameter
Lead Length
OUTPUT SENSITIVITY Figure 1
1.0” (25.4mm)
0.295”max (7.49mm)
15.0” (381mm)
100
Tests were conducted by exciting the left and right electrodes
with an AC signal of 400 Hz and an RMS voltage to produce the
maximum current at null as per operating specifications. Output
readings are taken between the center electrode and the center
of the balanced resistors R1 and R2. Tests were conducted at a
temperature of +25 C. See sensor test circuitry in figure 3.
Output curve is shown in figure 1.
PERCENT OUTPUT
80
Sensor Test Circuitry
60
40
20
0
-15
-10
-5
0
5
TILT ANGLE (arc minutes)
10
15
Descrition of Test Values
AC input voltage = Null
Current (max) times Null
Impedance (nom)
IMPEDANCE/TEMPERATURE
Figure 2
R1 =R2 = ½ Null Impedance
(nom)
IMPEDANCE Ohms)
5000
Eout = Angle of tilt from null
(Direction of tilt
determined by phase of
Eout)
4000
3000
2000
1000
0
Caution!-Ensure that all test and operating circuits are
entirely free of direct current. Direct current will cause level
damage and/or instability.
-20
-10
0
10
20
TEMPERATURE (degrees C)
The Fredericks Company l 2400 Philmont Ave ● HuntingdonValley, PA 19006-0067
Tel: 215.947.2500 l Fax: 215.947.7464 l Email: sales@frederickscom.com l www.frederickscom.com
0737-1203-99data sheet Revision: B
30
40
50
"