accelerometer MTN/11000 pages
DS0017 Issue 3 Page 1 of 2
Monitran Ltd Monitor House Hazlemere Rd Penn Bucks UK HP10 8AD
Tel: +44 (0) 1494 816569 Fax: +44 (0) 1494 812256 email: info@monitran.co.uk www.monitran.co.uk
Monitran reserves the right to alter the specification without prior notice
MTN/1100 Series
General purpose industrial accelerometer
Applications
· Data-collector
· Heavy industry
· Paper machinery
25mm A/F
51mm
Ø22mm
2 Pin MS
Technical Specification
Standard Sensitivity 100 mV/g ±10% Nominal at 80 Hz
Frequency Response 2 Hz to 10 kHz ±5% (-3 dB at 0.8 Hz)
Mounted Base Resonance 18 kHz (nominal)
Isolation Base isolated
Dynamic Range ±80g
Transverse Sensitivity Less than 5%
Electrical Noise 0.1 mg max
Current Range 0.5 mA to 8 mA
Temperature Range -55 to 140 ºC
Bias Voltage 12 Volts DC (nominal)
Case Material Stainless steel
Mounting Torque 8 Nm
Weight 110 gms (nominal)
Sealing IP67
Maximum Cable Length 1000 metres
Mounting Connector MTN/MH002
Options Integral cable, filters, temperature output,
various connector assemblies, other
sensitivities (see table)
sensitivities
ORDER CODE
PART No MOUNTING
xx = OPTIONAL
SENSITIVITY
RANGE AVAILABLE
(+/- 10%)
MTN/1100-xx
MTN/1100Q-xx
¼” UNF FEMALE
QUICK FIT FEMALE
FOR OTHER MOUNTINGS
SEE OVER PAGE.
10 mV/g
30 mV/g
50 mV/g
500 mV/g
1 V/g