Ventis slide-on pump0 pages
The Ventis Slide-on Pump is ideally suited for operators
that wear their gas monitor primarily for personal
protection but occasionally require a pump for confined
space entries. Available in black or safety orange and
powered by its own battery pack, the slide-on pump is
compatible with the Ventis MX4 and MX4 iQuad multi-gas
monitors.
■t onvenient sampling – Sample draw distance of
C
up to 50 feet provides convenient sampling in a wide
range of applications
Specifications*
Instrument Warranty:
Two-year warranty, excluding consumables (i.e. - filters)
Case Material:
Polycarbonate with protective rubber overmold
Sample Draw Capability:
Up to 15.2 meters (50 feet)
Dimensions:
143 mm x 81 mm x 68 mm (5.6" x 3.2" x 2.7") - Lithium-ion battery
version
143 mm x 81 mm x 85 mm (5.6" x 3.2" x 3.3") - Extended-range
lithium-ion battery version
143 mm x 81 mm x 73 mm (5.6" x 3.2" x 2.9") - Alkaline battery version
Weight:
270 g (9.5 oz) - Lithium-ion battery version
316 g (11.2 oz) - Extended-range lithium-ion battery version
284 g (10.0 oz) - Alkaline battery version
Operating Temperature Range:
-20°C-50°C (-4°F-122°F)
Operating Humidity Range:
15%-95% non-condensing (continuous)
Power Source/Run Time:
Rechargeable lithium-ion battery pack - 18 hours @ 20ºC
Rechargeable extended-range lithium-ion battery
Pack - 36 hours @ 20ºC
Replaceable AAA alkaline battery pack - 10 hours @ 20ºC
Pump Fault Alarms:
Ultra-bright LEDs
Loud audible alarm (90 dB at 30 cm)
IP Rating:
Third-party certified IP67
Certifications:
ATEXt ia I Ma and Ex ia IIC T4 Ga;
Ex
Equipment Group and Category: I M1 and II 1G
CSAt
Class I, Division 1, Group A B C D, T4 Exia; Ex ia IIC T4
IECExt ia IIC T4 Ga
Ex
ULt
Class I, Division 1, Groups A B C D, T4;
Class I, Zone 0, AEx ia IIC T4 Ga;
Class II, Group F G (Carbonaceous and Grain Dust)
MSHA: t
30 CFR Part 22; Permissible for underground mines;
t
Li-ion versions only
INMETROt Ex ia I Ma; Ex ia IIC T4 Ga
■t
Easy to attach – No tools are required to attach
or remove the Ventis Slide-on Pump to or from the
monitor
■t
Uses same battery packs and chargers as Ventis –
Monitor and pump each use the same battery packs,
and can easily be exchanged between instruments
■t
Flexible battery options – Three available battery
options make this pump extremely flexible in the field
*All specifications are based on a typical instrument and typical performance of the instrument.
As such, they are subject to vary.
The Gas Detection People
www.indsci.com
"