DAI SERIES PRESSURE TRANSMITTER
with Integrated Amplifier - mA or V output
The DAI Series offers – in addition to maximum
reliability – improved user friendliness in the form
of an Auto-Zero Function for local or remote
configuration. These models offer mA and V
output signals for further processing. The popular
and most commonly used 2- wire and 4...20mA
configuration provide unequalled interference in
critical environments.
Technical specifications DAI Series
Pressure range
0...50 to 0...2000 bar
•t Interference resistant signals over long distances
Accuracy incl. linearity, hysterisis,
and reproducability in % to
full scale
0,15 %, 0,25% or 0,5 %
•t 3- and 4- wire technology available
Reproducability in % to full scale
± 0,1%
Membrane coating
G-Coating
Resolution
16 Bit
•t Standard applications with process temps of uptt
to 300 °C (572 °F) possible
•t High temperature design for temperatures oft
up to 500 °C (932 °F)
•t Maximum reliability through new membranett
Max. pressure overload without
influence on operating value
2 x range up to 1000 bar
(14,500 psi)
1,5 x pressure range over 1000
bar (14,500 psi)
Bridge resistance
3500 Ohm Wheatstone Bridge
Supply voltage
19-32 V DC
Output signal
V or mA
Transmission medium
NTXTM as standard
Process connection
1/2”20 UNF or M18 x 1,5
Calibration point
80 %
Isolation resistance
>1000 MOhm at 50 V
Max. temperature at diaphragm
300 °C (572 °F) NTX
400 °C (750 °F) HG
500 °C (932 °F) NAK
Auto-zero Function
Max. temperature at terminal
head during operation
-40... +85 °C
(40 °F...185 °F)
auto-zero release in the sensor head
Zero point deviation against
diaphragm temperature changes
at the diaphragm % / ° C
( % / 1, 8 ° F )
± 0,02 bar / °C
(± 0,29 psi / °C)
Zero point deviation against
temperature changes at terminal
head in % / ° C ( % / 1, 8 ° F )
± 0,003 %
Ingress protection housing
Ingress protection connector
IP 65
IP 55
Max torque
1/2”20 UNF 30 Nm (22 lbf ft)
M18 x 1,5 50 Nm (32 lbf ft)
technology
•t Standard G-coating to counteract adhesivet
materials
Product variations (examples)
Highly accurate pressure sensors
Optional with an accuracy of 0.5%,
0.25% or 0.15% of full scale
As an option available with optical
"