SAE J514 Working Pressure Ratings0 pages
SAE J514 Working Pressure Ratings
Capable of 4 to 1 Minimum Burst
Note: In the case of a fitting that is a jump size, it is recommended that the lower pressure of the two ends must be recognized as
the working pressure rating for that fitting. This is also the case if the fitting has one or more different style ends. For example,
straight treads to pipe threads. In this case it is also recommended that the lower pressure rating of the two different style ends
must be recognized as the working pressure rating for that fitting.
Rigid SAE Rigid SAE
St. Thread St. Thread
Unions &
Unions &
Bulkhead
Bulkhead
MPa
PSI
Adjustable
SAE Std.
Thread &
Female
Swivel MPa
Adjustable
SAE Std.
Thread &
Female
Swivel PSI
Fittings
with
Pipe
Thread
MPa
Fittings
with
Pipe
Thread
PSI
NPSM Std.
NPSM Std.
Pipe Thread
Pipe Thread
Maximum
Maximum
Operating
Operating
Pressure
Pressure PSI
MPa
Nom
SAE
Dash
Size
Nom
Tube
O.D.
M.M.
Nom
Tube
O.D.
Inch
Straight
Thread
Size
2
3.18
0.125
5/16-24
1/8
34.5
5,000
34.5
5,000
34.5
5,000
34.5
3
4.76
0.188
3/8-24
1/8
34.5
5,000
34.5
5,000
34.5
5,000
-
-
4
6.35
0.250
7/16-20
1/8
34.5
5,000
31.0
4,500
34.5
5,000
34.5
5,000
Nom
Pipe
Size
5,000
5
7.94
0.313
1/2-20
1/8
34.5
5,000
27.5
4,000
34.5
5,000
-
-
6
9.52
0.375
9/16-18
1/4
34.5
5,000
27.5
4,000
27.5
4,000
27.5
4,000
8
12.70 0.500
3/4-16
3/8
31.0
4,500
27.5
4,000
21.0
3,000
24.1
3,500
10
15.88 0.625
7/8-14
1/2
24.0
3,500
21.0
3,000
21.0
3,000
-
-
12
19.05
0.750 1 1/16-12
3/4
24.0
3,500
21.0
3,000
17.0
2,500
15.5
2.250
14
22.22 0.875 1 3/16-12
3/4
21.0
3,000
17.0
2,500
17.0
2,500
-
-
16
25.40 1.000 1 5/16-12
1
21.0
3,000
17.0
2,500
14.0
2,000
13.8
2,000
20
31.75
1.250
1 5/8-12
1 1/4
17.0
2,500
14.0
2,000
8.0
1,150
11.2
1,625
24
38.10
1,500
1 7/8-12
1 1/2
14.0
2,000
10.5
1,500
7.0
1,000
8.6
1,250
32
50.30
2,000
2 1/2-12
2
10.5
1,500
8.0
1,125
7.0
1,000
7.8
1,125
SAE J1453 Working, Proof & Minimum
Face Seal Fittings
NOTE: In the case of a fitting that is a jump size, it is recommended that the lower pressure of the two ends must be recognized
as the working pressure rating for that fitting. This is also the case if the fitting has one or more different style ends. For example,
Face Seal to pipe threads. In this case it is also recommended that the lower pressure rating of the two different style ends must
be recognized as the working pressure rating for that fitting.
Straight Straight
Adjustable Adjustable
Non Straight Straight Straight Straight
Adjustable
Adjustable Adjustable
Adjustable
Fittings Fittings
Fittings
Fittings
SAE Fittings Fittings Fittings Fittings
Fittings
Fittings
Min.
Min.
Fittings
Fittings in.
Working
Working
Dash Working Working Proof
Proof
Min. Burst
Proof MPa Proof PSI
Burst PSI
Burst
Burst
MPa
PSI
Size
MPa
PSI
MPa
PSI
MPa
PSI
MPa
4
41.3
6,000
82.5
12,000
165
24,000
41.3
6,000
82.5
12,000
165.0
24,000
6
41.3
6,000
82.5
12,000
165
24,000
41.3
6,000
82.5
12,000
165.0
24,000
8
41.3
6,000
82.5
12,000
165
24,000
41.3
6,000
82.5
12,000
165.0
24,000
10
41.3
6,000
82.5
12,000
165
24,000
41.3
6,000
82.5
12,000
165.0
24,000
12
41.3
6,000
82.5
12,000
165
24,000
41.3
6,000
82.5
12,000
165.0
24,000
16
41.3
6,000
82.5
12,000
165
24,000
34.5
5,000
69.9
10,000
138.0
20,000
20
27.5
4,000
55.0
8,000
110
16,000
27.5
4,000
55.0
8,000
110.0
16,000
24
27.5
4,000
55.0
8,000
110
16,000
20.7
3,000
41.3
6,000
82.5
12,000
"