WIND Brochure0 pages
Ordering
Information
Communications
With an embedded web server, WebMaster® WIND utilizes standard TCP/IP Internet communications. Remote communications can
be established with WebMaster® WIND via the Internet or on a direct line with modem-to-modem capability. USB Plug and Play and
Ethernet are included to allow easy on-site access for plant personnel and system operators. Multiple users can access the
controller simultaneously. A graduated password protection system allows users varied degrees of access from view only to
full system configuration. In addition, WIND delivers a range of user-friendly information reporting tools including email notifications
for datalogs, alarms and system summaries.
Industrial Water Treatment Controllers
WIND8
1
Sensors
WebMasterONE is the most advanced online cooling
tower and boiler controller in the water treatment industry. The flexible multi-I/O platform allows you to
control multiple cooling towers, boilers, closed loops,
and condensate lines with just one controller. An
extensive assortment of integrated communications
and data handling features are included that enable
water treatment professionals to provide more effective
water management services to their customers.
2t 3t 4t 5t6
System Options
Walchem has made use of the Internet as a remote access communications platform for industrial control equipment a practical
reality. While others just attempt to reduce the cost of embedded web server hardware, Walchem has solved the problem of
the high cost and lack of availability of a permanent connection to the Internet.
1 SENSOR INPUTS REQUIRED
1 = One sensor inputt
3 = Three sensor inputs
2 = Two sensor inputst
4 = Four sensor inputs
WebMaster® WIND makes programming your process simple and fast and does not require any proprietary software to reside on
your computer. Set-up and programming are all done via a standard web browser.
2 VOLTAGE CODE
0 = Prewired w/USA power cord, 0 powered relays,
t
8 dry contact relays
1 = Prewired w/USA cords, 7 powered relays,
t
1 dry contact relay
2 = Prewired w/USA cords, 8 powered relays
3 = Prewired w/USA cords, 4 powered relays,
t
4 dry contact relays
4 = Hardwired, 0 powered relays, 8 dry contact relays
5 = Hardwired, 8 powered relays
6 = Hardwired, 7 powered relays, 1 dry contact relay
7 = Hardwired, 4 powered relays, 4 dry contact relays
E = Prewired w/ USA power cord, 4 powered relays,
t
4 opto-isolated (pulse) relays
F = Prewired w/ USA cords, 4 dry contact relays,
t
4 opto-isolated (pulse) relays
G = Hardwired, 4 powered relays, 4 opto-isolated (pulse) relays
H = Hardwired, 4 dry contact relays, 4 opto-isolated (pulse) t
trelays
Easy to follow menus and system set-up screens make programming user friendly and intuitive. Once WebMaster® WIND is
installed, the Start-up menu jump-starts you through the top level set-up. The Input, Output and Utility menus guide you through
the rest of the programming.
•t USB Plug and Play: For local monitoring and reconfiguration of tt
USB Plug & Play
t your WebMaster® WIND via LapTop or dedicated on-site PC.
Internet
•t ShoulderTap® Internet Communications: For monitoring and ttt
t reconfiguration of your WebMaster® WIND remotely via the
t Internet (requires landline modem card option).
ISP
Walchem Web Page
•t DirectTap Modem-to-Modem: For remote monitoring and
Modem
t reconfiguration of your WebMaster® WIND using traditional
t modem-to-modem communications (requires landline modem card option).
Modem
Modem
Modem
Phone Company
•t Ethernet: For monitoring and reconfiguration of your WebMaster® tt
t WIND via Local Area Network or remotely via the Internet. Modbus TCP/IP t
t is available to seamlessly connect to building energy & process manageInternet
t ment, distributed control, and SCADA systems
LAN
LAN
Cell Service
provider
•t Cellular: For monitoring and reconfiguration of your WebMaster
®
3 ANALOG OUTPUTS
N = No electrode
1 = One 4-20 mA output board
2 = Two 4-20 mA output boards
3 = Three 4-20 mA output boards
4 = Four 4-20 mA output boards
ETHERNET NETWORKING
4 INPUT OPTIONS
N = None
A = Analog Input board (8 inputs)
D = Digital Input board (6 inputs)
B = Both Analog and Digital Input boards
Walchem’s Ethernet Networking allows you to leverage the power of the WebMaster® WIND communications abilities. By using
the Local Area Network (LAN) or by connecting the WebMasters together via Ethernet, you can access all the controllers on the
network from a single phone line. By utilizing the existing LAN, wiring can be minimized. The controller simply plugs into the nearest
LAN connection via a standard Ethernet cable. The Master controller detects the other Walchem devices on the network and provides
a single point of access.
5 DIGITAL COMMS HARDWARE
(USB & ETHERNET STANDARD)
N = No additional communications
M = Modem landline card
G = Cellular Modem card (GPRS)
t WIND remotely via the Internet (requires cell modem and VTouch
toption).
VTouch Web Page
Internet
LAN
LAN
LAN
LAN
Internet
LAN
LAN
6 DIGITAL COMMS SOFTWARE
N = No additional communications
1 = Ethernet networking (Master capability)
2 = Modbus TCP
3 = Ethernet networking (Master capability + Modbus TCP)
WebMaster
Slave Units
WebMaster
Master Unit
WebAlert®
Slave Unit
180321.J Jan 2014
LAN
LAN
WebMaster® WIND
Webmaster®ONE
WebMaster® WIND sets a new standard for Industrial Water
Treatment Controllers. The WIND has a flexible multi-input/output
platform, a wide range of analytical sensor measurement capabilities,
and an extensive assortment of integrated communications and data
handling features.
Beyond the extensive list of capabilities, WIND has set an industry-wide
ease-of-use benchmark. All together, it represents the perfect balance
between Innovation, Flexibility, and Simplicity.
Metering Pumps
The E-Class is the most innovative and comprehensive
metering pump product line in the world. Over 50 years
of pump experience and a commitment to superior
mechanical design has led to development of many
industry firsts, including 360 stroke-per-minute
technology, IP67 waterproof construction, and the
world’s highest capacity solenoid metering pumps.
Summary of Key Benefits
WebAlert® Remote Monitor
Fully integrates functions of a transmitter, PLC, datalogger and auto-dialer into a rugged, industrial,
NEMA 4X package
Walchem’s WebAlert is the first stand alone remote
monitoring device that can web enable your installed
equipment without having to replace or upgrade it.
No proprietary software required to view live data - just a web browser
Access live or stored data remotely within the facility (LAN connection) or from anywhere in the world
(cell or landline modem)
No expensive PLC programming and re-programming – all changes made intuitively using a standard
web browser
VTouch® provides quick, centralized 24/7 awareness of account status with the ability to LIVE Connect
to any of your controllers in the field with one simple mouse-click.
AGENCY CERTIFICATIONS
Safetyt
ANSI/UL 61010-1:2012 3rd Ed.
t
C22.2 No. 61010-1:2012 3rd Ed.
t
IEC 61010-1:2010 3rd Ed.
t
EN 61010-1:2010 3rd Ed.
EMCt
IEC 61326-1:2005
t
EN 61326-1:2006
Note: For EN61000-4-6,-3 the controller met performance criteria B.
*Class A equipment: Equipment suitable for use in establishments
other than domestic, and those directly connected to a low voltage
(100-240 VAC) power supply network which supplies buildings used
for domestic purposes.
Extensive built-in Plug & Play communications options:
•t Ethernet t
•t USB (Laptop and FlashDisk support)
t
•t Landline modemt
•t Cell modem
t
A wide range of direct sensor measurements:
•tpHt
•t ORPt
t
•tChlorine Dioxidet
•t Ozone t
t
•t Conductivityt
•t Peracetic Acidt
•t Free Chlorine
•t Electrodeless Conductivity
PID control for relay and analog outputs
Instant alarm notification via cell phone text message, email, or local alarm relay
ABOUT US
Walchem integrates its advanced sensing, instrumentation,
fluid pumping and communications technologies to deliver
reliable and innovative solutions to the global water treatment market. Our in-house engineering is driven by quality,
technology and innovation. For more information on the
entire Walchem product line, visit: www.walchem.com.
Walchem, Iwaki America Inc.
Five Boynton Road Hopping Brook Park
Holliston, MA 01746 USA
Phone: 508-429-1110 www.walchem.com
System status reports and datalog files can be emailed automatically
Disinfectiont
Water Treatmentt
Wastewater Treatmentt
Pools/Spas
"