Open-loop Hall effect current sensor 30 * 40 mm, 300 - 2000 A | SCK18 series0 pages
Socan SCK18 technical parameters
Open Loop Current Sensor
SCK18-
Model
Parameters(25°C)
300A
400A
500A
600A
800A
1000A
1200A
1500A
2000A
Nominal Rms Current (Ipn) ±300AT ±400AT ±500AT ±600AT ±800AT ±1000AT ±1200AT ±1500AT ±2000AT
Measuring Range (Ip)
2*Ipn
Load resistance Rmax
≥10k ≥10k
Output Voltage
±4V
Working voltage
DC ±12V~±15V(±5%)
Accuracy @ Ta=25°C
±1% FS
Linearity @ Ta=25°C
±1% FS
Withstand voltage
3kVrms/50Hz/min
Offset Voltage
< ±30mV
Offset temperature
< ±0.1%/°C
characteristics
Thermal drift of Vo
< ±1mV/°C (If=0)
Response time
< 5uS
Hysteresis offset
< ±25mV (if=F.S. 0<--- --->Nominal RMS Current)
Current consumption
<±15mA
Operating temperature
-20~+80 °C
Storage temperature
-40~+85 °C
Dimension (mm)
Window size 30*40
Instructions
1.SCK18 Series is open-loop current sensor. There is galvanic isolation between primary and secondary circuit of the sensor,
it can measure DC, AC or pulse currents.
2.Big square perforation, mainly measure cooper conductor current.
3.Features: High accuracy, low power consumption, high liability and strong overload capacity.
Caution: Incorrect wiring may damage the sensor
Shenzhen SoCan Technologies Co.,Ltd
T: 86-0755-86242301 F: 86-0755-86242302
URL: www.SZSOCAN.COM