تماس با ما
وب سایت در حال به روز رسانی است. از شکیبایی شما سپاسگزار هستیم.

منابع یابی و خرید تجهیزات صنعتی

محصولات
محصولات
سازندگان
کاتالوگ
فیلم

 (ویژه صنایع و کارخانجات )

خدمات خرید ، حمل ، ثبت  سفارش ، ترخیص و تحویل هر گونه کالای صنعتی از اروپا ، چین ، ترکیه  و امارات متحده عربی
لطفا جهت خرید ، حمل ، ترخیص و تحویل هر گونه کالای صنعتی در هر نقطه از دنیا با ما در تماس باشید .
ایمیل sales@meshgad.com
تلفن تماس 41995-021

  • 1
  • 2
  • 3
  • 4
  • 6
LOADING

Motor Actuated Valve Application Guide0 pages

نسخه متنی
"

www.clarksol.com CLARK SOLUTIONS Motor Actuated Valve Application Bail Valves, Globe Valves & Butterfly Valves INTRODUCTION The control valve is one of the most important items in a flu-idic system. If greater attention were paid to the proper siz-ing and application of control valves there would be fewer flow control problems. A valve that is undersized can result in insufficient flow at design conditions. An oversized valve is subject to instability as it attempts to control flow over a very small portion of its overall flow range. In effect, an oversized valve will have a much greater change in flow for the same change in signal as a properly sized valve. FLOW COEFFICIENT (CV) Guide The single most important piece of information needed to select a control valve is the valve sizing coefficient, Cv. Cv is defined as the flow rate in U.S.gallons of water (at 60°F) that will pass through the valve in one minute with a differential pressure across the valve of 1 PSI. A valve's Cv is unique to the size, angle of open-ing and manufacturer's style. The information to consider in determining the Cv includes: Variable Water Steam Chemicals Line Size size (inches) size (inches) size (inches) Flow Rate of Application GPM LBS/Hr or BTUH GPM Pressure Drop (DP)of the Coil or Application PSID PSID PSID Temperature of Fluid °F °F °F Chemical Type %Glycol (if any) Any Additives? Specify Type Additive Concentration NA NA % When these variables are known, the Cv required for the application can be determined using the formulas on the following pages of this bulletin. Regardless of the Cv, the valve size should not exceed the line size. For modulating applications, it is typically one or two sizes smaller than line size. CONTROL VALVE PRESSURE DROP In most instances, the only variable when calculating the Cv required of the valve is the pressure drop (DP) across the valve. The pressure drop across a valve is always measured with the valve fully open. In HVAC applications the heat exchange coil has typically been selected (or already exists) before the valve is cho-sen, therefore the GPM and pressure drop of the coil should be known. For optimal control, the pressure drop across the control valve should be equal to, or slightly greater than, the pressure drop of the coil and its fittings. This will ensure that the valve will control the flow through the coil through its entire range of travel. When controlling flow for a non-coil application, the same principle applies as indicated above for coil applications. Whatever the valve is directly controlling should be viewed as a system with a specific opening at the valve. The pressure upstream and downstream of the system determine the amount of flow through the system. Therefore, the ideal pressure drop across the control valve should be equal to, or greater than, the pressure drop of the system that is being controlled. WATER APPLICATIONS Two-Position Control -Ball,globe or butterfly valves can be used for this application. -The pressure drop across the valve should be low (usually less than 2 PSI)in its open position. -Valves for this purpose are typically selected at line size to minimize installation cost and pressure drop. In some applications, ball and butterfly valves can be used one size smaller than line size without dropping enough pressure to affect system performance. Modulating Control -The pressure drop across a two-way valve should be equal to,or slightly greater than,the pressure drop of the coil and its fittings. On a three-way valve,the pressure drop is based on the drop between the common port of the valve and the port which you are trying to control (with the port fully open). A typical coil pressure drop for HVAC applications is usually 3 PSI or less. This is the reason why a 3-5 PSI pressure drop across the valve has been used as a rule of thumb. Clark Solutions ͕ 10 Brent Drive Hudson, MA 01749 Օ Tel. 978 / 568 3400 Fax 978 / 568 0060

"

IRAN INDUSTRY EXPO

The largest online Industrial exhibition in Iran

 عضویت ورود   ENGLISH


اگر مجموعه شما جزو صنایع مادر و معظم در فیلد پالایشگاه ، پتروشیمی ، حفاری ، نیروگاه ، معادن و فلزات ، خودروسازی ، تولید مواد غذایی و.... می باشد لطفا درخواست خود را بر روی سربرگ به فاکس 88206264 و یا ایمیل enquiry@iranindustryexpo.com بنام شرکت مهندسی و بازرگانی مشگاد ارسال فرمایید.
اگر مجموعه شما جزو بنگاه های متوسط و کوچک در فیلد تولید ، بازرگانی ، مشاوره ، پیمانکاری ، دانشگاه ، پژوهشگاه ، توزیع ، فروشگاهی وکارگاهی می باشد ، پس از عضویت و با پرداخت هزینه ( به ازای هر درخواست معادل 50 یورو ) از خدمات زیر برخوردار خواهید شد :
  • پاسخ به پرسش های فنی و دریافت مشاوره از سازنده ، دریافت کاتالوگ و اطلاعات تکمیلی
  • دريافت پرفورما از شرکت سازنده
  • اطلاع از زمان تحويل و قيمت خالص كالا
  • اطلاع از هزينه هاي حمل و ترخيص و کارمزد تا تحويل كالا به انبار شما در هر نقطه از كشور
  • دریافت پیش فاکتوررسمی ( ارزی و یا ریالی ) به روش کارمزدی
*صدور پیش فاکتور رسمی فقط به نام شرکتهای ثبت شده که دارای کد بازرگانی معتبر باشند انجام پذیر است. در صورتیکه در حین مکاتبه با شرکت سازنده مشخص شود که دارای نماینده انحصاری و یا شعبه در ایران بوده و یا به به هر دلیل شرکت سازنده از فروش کالا به بازار ایران استنکاف نماید ارایه این سرویس متوقف و وجه دریافتی به حساب کاربر عودت می شود

ادامه