Motors wound for 330 Vac phase to phase0 pages
TECHNICAL CHARACTERISTICS
Motors wound for 330 Vac phase to phase
145STK2M
Rated speed
Continuous torque
Current at continuous torque
NATURAL CONVECTION
Peak torque
145STK8M
500
500
500
N.m
(1)
(2)(3)
145STK6M
500
rpm
(1)(4)
145STK4M
1500
14.6
A
2.3
5.2
N.m
1500
26.4
3.7
9.2
55
1500
37.3
5
12.7
110
1500
47.4
6.4
15.7
165
220
Current at peak torque
(2)
A
10.2
23.1
17.8
45.5
27.3
68.3
35.6
91.1
Rated power
(1)
W
735
2032
1247
3134
1775
3480
2200
3850
Inertia
10-3kg.m²
1.28
2.24
3.19
4.14
Weight
kg
6.2
10.4
14.5
18.7
Thermal time constant
(1)
s
1012
1399
1667
1866
Thermal resistance
(1)
°C / W
0.394
0.324
0.275
0.239
Phase resistance at 20°C
(2)
Phase inductance at I continuous
12.9
Electrical time constant
(2)
(2)
V/rad.s
6.2
0.95
3.46
0.55
2.51
0.38
12.4
44.5
6.8
28.2
4.5
22.2
3.4
1.91
4.88
1.91
4.78
1.91
4.88
ms
Back emf constant (line to line)
2.55
66.7
mH
Power cable square section
nxmm
Power cable diameter
5.1
4.25
2
7.2
8.2
8.9
1.91
4x1.5
4x1.5
4x1.5
4x1.5
Ø8
Ø8
Ø8
Ø8
mm
Number of poles
12
145STK2M
(4)
WINDING AT 60°C
Fluid input temperature
145STK4M
145STK6M
145STK8M
22.8
45.3
67.6
90
N.m
Current at continuous torque
FLUID-COOLED MOTORS
COMPLEMENTARY DATA FOR
Continuous torque
A
(5)(6)
3.5
°C
8
6.3
20
15.6
9
22.8
20
12.1
20
29.8
20
Fluid temperature rise
°C
5
5
7
8
Housing temperature
°C
< 30
< 30
< 30
< 30
Fluid f low
l / mn
3
3
3
3
W
620
930
1220
1510
Losses
Pressure drop
Bar
4x1.5
4x4
4x1.5
4x4
Ø8
Ø8
Ø8
Ø11.1
Ø8
Ø11.1
145STK4M
N.m
WINDING AT 140°C
Current at continuous torque
FLUID-COOLED MOTORS
COMPLEMENTARY DATA FOR
(4)
4x1.5
145STK2M
Continuous torque
0.3
4x1.5
mm
Power cable diameter
0.2
nxmm2
Power cable square section
Fluid input temperature
29.9
A
(5)(6)
5.4
12.3
0.4
0.5
145STK6M
59.8
145STK8M
90
9.7
24
14
120
35.5
19
46.8
°C
Housing temperature
20
20
20
20
°C
Fluid temperature rise
8
8
10
12
°C
33
29
29
31
l / mn
3
5
5
5
Losses
W
1532
2240
2950
3660
Pressure drop
Bar
0.2
0.7
1
1.3
Fluid f low
Power cable square section
Power cable diameter
nxmm
2
4x1.5
4x4
4x1.5
4x6
4x2.5
4x10
Ø8
mm
4x1.5
Ø8
Ø11.1
Ø8
Ø13.4
Ø9.6
Ø16.7
(1) Thermal conditions:
Ambient temperature 20°
C
Winding temperature rise 120°
C
Stator housing in contact with the ambient air or integral on all its peripheral area with a metallic armature in contact with the ambient air.
Stator housing secured on a metallic frame having an area equal to twice the cross section of the housing.
(2) Cold motor at 20°
C
(3) See torque vs speed characteristics on :
http://www.alxion.com/CFN
(4) Torque at stall or low speed.
(5) Fluid input temperature should not be lower for avoiding condensation inside the motor.
(6) For cooling fluid, use softened gycol-added water or fluids approved for closed cooling circuits.
Other speed characteristics are available, please contact us.
7