HY-OPTIMA 730 Process Hydrogen Analyzer Data Sheet0 pages
Technical Data and Specifications | |||
àscari Hydrogen is the future, we can sense it! ™ | |||
HY-OPTIMAIM 730 In-line Process Hydrogen Analyzer (ppm H2S & CO) • CO and H2S Tolerance Description |
H2scan's Series 700 in-line, real-time hydrogen specific process analyzers are designed for ease of use, interface
nnnnflexibility and true process control. The HY-OPTIMA 730 is a solid-state sensor configured to operate in
nnnnbackground gas streams having carbon monoxide concentrations up to 100 ppm, hydrogen sulfide stream
nnnnconcentrations up to 1000 ppm, up to 95% relative humidity, and temperatures up to 100°C. The HY-OPTIMA™
nnnn730 is ideal for hydrogen production and petrochemical applications where real-time measurements of hydrogen
nnnncan increase process plant efficiencies, improve diagnostics and enhance maintenance management translating
nnnninto higher profitability.
nnnnPerformance
nnnnOperating Conditions
nnnnHydrogen Sensitivity Range:
nnnn0.5% to 100% hydrogen at 1 ATM on a
nnnnvolume basis in a single or multi-component
nnnngas background
nnnnTypical Response Time: T90 less than 30 sec
nnnnIngress Protection: IP64 capable
nnnnRecommended Verification Interval: 90 days
nnnnProduct Life Expectancy: 10 years
nnnnAccuracy(*):
nnnn± 0.15% absolute for 0.5 to 10% H2
nnnn± 0.50% absolute for 10 to 100% H2
nnnnDrift/week:
nnnn± 0.10% absolute for 0.5 to 10% H2
nnnn± 0.20% absolute for 10 to 100% H2
nnnnRepeatability:
nnnn± 0.10% absolute for 0.5 to 10% H2
nnnn± 0.20% absolute for 10 to 100% H2
nnnnLinearity:
nnnn± 0.10% absolute for 0.5-10% H2
nnnn± 0.20% absolute for 10-100% H2
nnnnInterface Options_
nnnnInput Voltage Range: 8 VDC to 13 VDC
nnnnInput Current: 1.0 A
nnnnAnalog Outputs:
nnnnOutput Voltages - OR -
nnnn• 0 VDC to 5 VDC
nnnn• 1 VDC to 5 VDC
nnnn• 0 VDC to 4 VDC
nnnn• 0.5 VDC to 4.5 VDC
nnnn• User-specific VDC range
nnnnSerial Communication Options: RS232 or RS422
nnnnRelay Contacts: Two programmable 60 VDC /1 A
nnnnSPDT relays with both normally open (N.O.)
nnnnand normally closed (N.O) contacts
nnnnOutput Currents
nnnn• 4 mA to 20 mA
nnnn• 0 mA to 20 mA
nnnn• User-specific mA range
nnnnCertifications: C(^L)US LISTED Q £
nnnnProcess Gas Tolerance:
nnnnCO tolerance < 100 ppm
nnnnH2S tolerance < 1000 ppm
nnnnOperating Humidity: 0% to 95% RH
nnnnFlow Rate: 0.1 slpm to 50 slpm
nnnnPressure: 0 to 7 bar gauge, 0 to 100 psi gauge
nnnnProcess Gas Temperature Range: -20°C to 100°C
nnnnOperating Temperature Range: -20°C to 40°C
nnnnStorage Temperature Range: -40°C to 50°C
nnnnCalibration Background Gas: Nitrogen
nnnnAdapter Fittings
nnnn1/2in. MNPT thread
nnnn1/2in. FNPT thread
nnnn-8 SAE/MS thread size
nnnn... and many other industry standards
nnnnDimensions
nnnnTotal Length: 9.1 in.
nnnnLength of Enclosure: 6.7 in.
nnnnLength of Tube: 2.4 in.
nnnnWidth: 3.4 in.
nnnnDepth: 1.4 in.
nnnn* Sensor performance specifications are only valid for units configured for a maximum 65°C dry process stream temperature. All figures
nnnnassume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The
nnnnaccuracy is specified for serial port output only.
nnnnHY-OPTIMA is a registered Trademark of H2scan
nnnnSpecifications subject to change without prior notice
nnnn90000017 R5
nnnn27215 Turnberry Lane, Unit A, Valencia CA, 91355
nnnnTel: 661-775-9575, Fax: 661-775-9515