Navigation Controller (BRC1E71) Brochure0 pages
Navigation Remote Controller
(Wired Remote Controller)
BRC1E71
Simple operation. Large and clear display.
Auto-changeover. Advanced scheduling.
Independent setpoints control.
The Navigation Remote Controller is the latest addition to Daikin’s
controls suite which offers scalable control architecture optimized for
VRV and SkyAir technology. The wall mounted controller features a
backlit LCD display as well as intuitive menus. The menu displays are
now available in English, French, or Spanish languages.
Basic Operation
n
n
O
n/Off, Operation mode, Setpoint, Fan speed
A
irflow direction (Menu)
Function
n
n
n
n
n
t
S
etpoint range limit (Service menu)
I
ndividual button prohibit (Service menu)
I
ndependent occupied and unoccupied (setback) heating
and cooling setpoints
A
uto-changeover with cooling and heating setpoints, for
heat pump and heat recovery systems
S
chedule
n eekly schedule – 7 days (7), weekday plus weekend
W
(5+2), or weekday plus Saturday plus Sunday (5+1+1)
configurable
n ive events per day – On (with individual cooling and
F
heating setpoints), Off (with individual Setup/Setback
setpoints)
Off Timer
Schedule
Tue
Time
– 6 :00 A
– 8 :00 A
– 5 :30 P
1 0 :00 P
– – :– –
Act
ON
OFF
ON
OFF
––
Cool
75F
85F
75F
82F
Heat
70F
50F
70F
62F
–
Current Setting
After you turn on the unit,
it will automatically
turn off in
Air Flow Direction
Ventilation Rate
Ventilation Mode
Schedule
Off Timer
Display
–
60 minutes.
1/2
Swing
Low
Auto
Enable
Disable
Standard
Setting
Setting
Setting
Weekly schedule
Guide on display
All status on display
Main Menu
2/2
Configuration
Current Settings
Clock & Calendar
Daylight Saving Time
Language
Cool
Set to
Cool 74F
Cool
Set to
Cool 74F
AUTO
Time to clean filter
Setting
Eng./Fr./Sp. language
selectable
Maintenance notice
ERV
Error : Press Menu button
Error notification
For use with:
Display
n
t
n
t
n
S
tandard display mode
n peration mode, Occupied and unoccupied setpoint(s),
O
Fan speed
D
etailed display mode
n peration mode, Occupied and unoccupied setpoint(s),
O
Fan speed, Airflow direction, Room temperature,
Day, Time
E
rror code, System status
(centralized control, master controlled)
Others
A B SO L U T E C O MF O RT
n
n
n
n
n
n
B
acklit
R
oom temperature sensor
1
2/24 hour clock
F
ahrenheit/Celsius selectable
E
nglish/French/Spanish (buttons and system status displays
are in English only)
R
emote control group – up to 16 indoor units
DAIKIN AC
Backwards compatible with BRC1D71
"